MVSG Electrical is an indoor metal-enclosed medium voltage switchgear assembly for receiving, distributing and switching electrical power within medium-voltage distribution systems.
Technical Parameters
|
Parameter |
Specification |
|
Product Type |
Indoor Metal-Enclosed Medium Voltage Switchgear |
|
Rated Voltage |
3 / 6 / 10 kV |
|
Rated Frequency |
50 Hz |
|
Rated Current |
630–5000 A |
|
Short-Time Withstand Current |
20 / 25 / 31.5 / 40 kA |
|
Short-Circuit Duration |
4 s |
|
Peak Withstand Current |
50 / 63 / 80 / 100 kA |
|
Power-Frequency Withstand Voltage |
42 / 48 kV, 1 min |
|
Lightning Impulse Withstand Voltage |
75 / 85 kV |
|
Main Switching Device |
Withdrawable Vacuum Circuit Breaker |
|
Enclosure Protection |
IP4X |
|
Internal Compartment Protection |
IP2X |
|
Installation |
Indoor |
Four Functional Compartments
MVSG Electrical separates the main equipment into four functional compartments, with each area assigned to a defined part of the primary or secondary circuit.
Busbar Compartment
Contains the main busbar system and primary connections between panels. The busbar arrangement follows the specified panel current rating.
Circuit Breaker Compartment
Houses the withdrawable vacuum circuit breaker and its operating mechanism.
Cable Compartment
Provides the cable connection area for incoming and outgoing circuits and associated primary connections.
Relay & Instrument Compartment
Contains protection relays, meters, control switches, indication devices, terminals and secondary wiring.

Protection and Interlocking
The withdrawable breaker mechanism coordinates breaker movement, primary contact access, grounding operation and cabinet access through defined mechanical sequences.
Breaker Position
The breaker operates in defined connected and test/disconnected positions. The position indicates whether the breaker is connected to the primary circuit.
Shutter Mechanism
When the breaker is moved away from the connected position, the shutter covers the relevant primary contact area.
Grounding Interlock
The grounding mechanism is coordinated with the breaker position to maintain the specified operating sequence during isolation and grounding.
Door Interlocking
The cabinet door and operating mechanism are mechanically coordinated to control access to the relevant primary equipment.
Position Indication
Mechanical indication identifies the breaker position at the cabinet.
Panel Configurations
Incoming Feeder Panel: Connects the upstream medium-voltage source to the main busbar.
Outgoing Feeder Panel: Connects the busbar to downstream medium-voltage circuits.
Transformer Feeder Panel: Provides the medium-voltage switching connection between the switchgear and transformer.
Bus Coupler Panel: Connects two busbar sections where the distribution arrangement requires controlled interconnection.
Metering / PT-VT Panel: Provides the panel arrangement for voltage measurement, metering and related protection functions.

Applications
MVSG Electrical is configured around the incoming supply, downstream circuits and busbar arrangement defined for each medium-voltage distribution project.
Utility-Fed Distribution
Used for medium-voltage incoming supplies from utilities or substations and distribution to downstream circuits.
Industrial Plant Distribution
Configured for medium-voltage distribution between incoming supplies, transformers, motors and production loads.
Generation-Related Distribution
Applied to medium-voltage connections between generating equipment, auxiliary transformers and downstream distribution systems.
Sectionalized Distribution
Configured for systems using separate busbar sections and controlled interconnection between sections.

Manufacturing Process
MVSG Electrical is assembled within WWE Group's electrical equipment manufacturing operation, supported by a manufacturing base of more than 200,000 m² and more than 120 pieces of production equipment. The production operation covers mechanical processing, spraying, instrumentation and electrical assembly.
Cabinet & Busbar Fabrication
The metal enclosure is fabricated according to the specified panel dimensions and compartment arrangement. The main busbar system is assembled according to the required current rating and panel configuration.
Primary Electrical Assembly
The withdrawable vacuum circuit breaker and other primary components are installed in their designated compartments according to the approved equipment configuration.
Secondary Electrical Assembly
Protection relays, meters, control switches, terminals and secondary wiring are installed in the relay and instrument compartment according to the electrical drawings.
Mechanical Integration
The withdrawable breaker mechanism, shutter mechanism, grounding mechanism and associated interlocking components are assembled with the cabinet structure and primary equipment.
FAQ
Q: What is a withdrawable vacuum circuit breaker?
A: A withdrawable vacuum circuit breaker is mounted on a withdrawable mechanism that allows the breaker unit to be moved between defined positions within the switchgear cabinet.
Q: What determines the required short-circuit rating of medium voltage switchgear?
A: The required short-circuit rating is determined by the prospective short-circuit current at the installation point and the electrical requirements specified for the distribution system.
Q: What technical documents are provided with MVSG Electrical?
A: The documentation package can include the technical datasheet, general arrangement drawing, single-line diagram, wiring diagram, component list, technical specification, inspection records, test documentation and operation documentation. The final document set corresponds to the equipment configuration supplied.
Q: Can project-specific drawings be provided?
A: Project-specific general arrangement drawings, single-line diagrams and wiring diagrams can be prepared from the confirmed panel arrangement and electrical configuration.
Q: What information is required for an MVSG Electrical quotation?
A: The main information includes rated voltage, rated current, frequency, short-circuit level, panel functions, CT/VT requirements, protection relay requirements, metering requirements and cable entry arrangement.
Q: Is a single-line diagram required when requesting a quotation?
A: A single-line diagram is not essential for every preliminary inquiry, but it provides a clearer reference when the project includes multiple feeders, transformer connections, bus couplers or a defined protection scheme.
Q: What information is needed to specify CT and VT requirements?
A: The required CT or VT ratio, measurement or protection function and relevant secondary requirements should be provided when these components form part of the switchgear configuration.