The XGN2-10 Electrical Ring Main Unit is a fixed medium voltage switching assembly designed for ring-network distribution arrangements in which incoming and outgoing circuits are operated, isolated and grounded within the same metal-enclosed lineup.

Technical Specifications
|
Parameter |
Specification |
|
Model |
XGN2-10 |
|
Product Type |
Fixed metal-enclosed medium voltage switchgear |
|
Installation |
Indoor |
|
System |
Three-phase AC |
|
Rated Frequency |
50 Hz |
|
Rated Voltage |
3 / 6 / 10 kV |
|
Rated Current |
630 / 1000 / 1250 / 1600 / 2000 / 2500 / 3150 A |
|
Rated Short-Circuit Current |
20 / 25 / 31.5 / 40 kA |
|
Rated Peak Withstand Current |
40 / 80 / 100 kA |
|
Rated Short-Time Withstand Duration |
4 s |
|
Power-Frequency Withstand Voltage |
42 kV |
|
Withstand Voltage Across Open Contacts |
48 kV |
|
Lightning Impulse Withstand Voltage |
75 kV |
|
Lightning Impulse Withstand Across Open Contacts |
85 kV |
|
Protection Degree |
IP2X |
|
Ambient Temperature |
-25°C to +40°C |
|
Relative Humidity |
Daily average ≤95%; monthly average ≤90% |
|
Altitude |
≤1000 m |
|
Seismic Condition |
Earthquake magnitude ≤8 |
|
Environmental Restrictions |
No fire or explosion danger, serious pollution or chemical erosion |
|
Standard Cabinet Dimensions |
1100 × 1200 × 2650 mm |
|
High-Current Cabinet Dimensions |
1200 × 1200 × 2650 mm |
|
Cabinet Width for Rated Current ≥2000 A |
1200 mm |
|
Vacuum Circuit Breaker Mechanical Life |
10,000 operations |
|
Standards |
GB3906 and IEC298 |
Ring-Network Configuration
The XGN2-10 is arranged as a fixed switching point within a medium voltage ring network, with incoming and outgoing circuits connected through the same switchgear lineup.
Typical Circuit Roles
- Incoming feeder
- Outgoing feeder
- Ring-network section
- Bus section where required
- Grounding point for maintenance
The lineup arrangement is defined by the project single-line diagram and required switching points.

Switching Equipment
The XGN2-10 uses different switching and operating components to perform circuit breaking, isolation and grounding functions.
|
Equipment |
Listed Options |
Function |
|
Vacuum Circuit Breaker |
ZN28A-12, ZN28-12, ZN63-12 (VS1) |
Circuit breaking |
|
Operating Mechanism |
CD10, CD17, CT8/CT19A(B), CT17, CT19 |
Circuit-breaker operation |
|
Isolation Switch |
GN30-10, GN22-10 |
Electrical isolation |
The selected combination is confirmed in the approved technical configuration.
Switching Sequence & Interlocking
The XGN2-10 uses forced mechanical locking between the circuit breaker, upper and lower isolation switches, grounding switches and cabinet doors.
Operating Relationship
Circuit breaking → Isolation → Grounding → Cabinet access
The interlocking arrangement controls the permitted sequence between circuit breaking, isolation, grounding and access to the relevant cabinet areas.
WWE's product documentation identifies this mechanical arrangement as meeting the stated five-prevention safety requirements.

Cabinet Construction
Breaker Compartment
The breaker compartment incorporates a pressure-release channel for gas discharge in the event of an internal electrical arc.
Busbar Support
The main busbar is connected to the upper isolation-switch terminals and supported by epoxy insulators with a stated mechanical strength of at least 8000 N.
Cable Connection
The cable compartment is positioned at the lower rear section, with cables fixed on supporting stands.
Insulation Support
Where the air insulation distance between phases or between phase and ground is 125 mm or less, porcelain support insulators with a stated mechanical strength of at least 8000 N are specified.
Project Information Required for Quotation
To prepare an XGN2-10 project quotation, provide the following information where applicable.
Electrical Requirements
System voltage
Rated current
Short-circuit level
Frequency
Circuit Arrangement
Single-line diagram
Incoming/outgoing circuit arrangement
Number of panels
Feeder functions
Switching & Protection
Circuit breaker
Isolation and grounding arrangement
Operating mechanism
Protection and measurement requirements
Site & Documentation
Special site conditions
Drawing requirements
Inspection requirements
Applicable project standards
A single-line diagram and electrical ratings provide the primary reference for quotation review.
WWE Manufacturing
Manufacturing History
Worldwide Electric was established in March 2000 and obtained ISO 9001 quality certification in May 2001.
Production & Testing Infrastructure
The manufacturing base in Xiangyang, Hubei covers more than 200,000 m² and includes mechanical processing, spraying, instrumentation and electrical assembly workshops. The company reports more than 120 sets of production and testing equipment and annual production exceeding 10,000 sets of high- and low-voltage switch equipment, motor starting equipment and reactive power compensation panels.
Export Coverage
Worldwide Electric states that its products have been exported to more than 50 countries and regions, including markets in East Asia, Southeast Asia, Central Asia, Africa, South America, North America and Europe.
Technical Resources
The company reports a National Enterprise Technology Center and an R&D center, together with 52 national patents and 17 products that have passed scientific and technological achievement appraisal in Hubei Province.
Project Support
The company states that its service team can assist with installation, debugging and testing. Technical training covers product principles, operating procedures, troubleshooting, overhaul warnings and maintenance.
Factory Inspection
Each XGN2-10 unit is inspected before shipment according to the approved technical configuration and purchase order requirements.
FAQ
Q: What is the MOQ for the XGN2-10 Electrical Ring Main Unit?
A: The standard MOQ is 1 complete unit or 1 project order. Multiple-panel quantities are confirmed according to the approved project configuration.
Q: What is the typical lead time for XGN2-10 switchgear?
A: The typical lead time is 30–45 days after technical specifications, drawings and commercial terms are confirmed. The schedule varies with quantity and configuration.
Q: What payment terms are available for XGN2-10 orders?
A: Payment terms are agreed according to order value, project requirements and contract conditions. Common arrangements include a deposit with the balance before shipment.
Q: How is the XGN2-10 packaged for export?
A: Packaging is selected according to the cabinet structure, transport method and destination. Wooden cases or equivalent external protection can be used for export shipments where required.
Q: What warranty is provided for the XGN2-10?
A: A standard 12-month warranty from shipment is normally provided for manufacturing defects, subject to the agreed warranty terms.
Q: Can buyers specify inspection requirements before production?
A: Yes. Buyer inspection requirements can be reviewed before production and incorporated into the approved project documentation.
Q: Can third-party inspection be arranged for XGN2-10 orders?
A: Yes. Third-party inspection can be arranged when required by the buyer, EPC contractor or project specification, with the scope and timing agreed in advance.