Medium Voltage Cubicle is a fixed metal-enclosed switchgear assembly for receiving, distributing and controlling electrical power in medium voltage distribution systems.

Technical Specifications
|
Parameter |
Specification |
|
Model |
XGN2-10 |
|
Product Type |
Fixed metal-enclosed medium voltage cubicle |
|
Rated Voltage |
3.6 / 7.2 / 12 kV |
|
Rated Frequency |
50 Hz |
|
Phase |
Three-phase AC |
|
Installation |
Indoor |
|
Power-Frequency Withstand Voltage |
42 kV |
|
Power-Frequency Withstand Voltage Across Isolating Fracture |
48 kV |
|
Lightning Impulse Withstand Voltage |
75 kV |
|
Lightning Impulse Withstand Voltage Across Isolating Fracture |
85 kV |
|
Mechanical Life of Vacuum Arc-Chute |
1,000 operations |
|
Mechanical Life of Isolating and Earthing Switch |
2,000 operations |
Internal Arrangement
Busbar Section
The busbar section provides the main electrical connection between the cubicles in the switchgear lineup.
Switching Section
The switching section accommodates the primary switching device and its operating mechanism.
Cable Section
The cable section provides the connection between the primary circuit and the external medium voltage cable system. The component arrangement varies according to the selected circuit.
Secondary Equipment Section
The secondary section accommodates the protection, measurement, control and indication devices required by the electrical scheme.
Enclosure and Observation
The metal enclosure surrounds the primary electrical components. An observation window allows the internal switching condition to be checked without opening the main enclosure.
Circuit Function and Primary Equipment
Incoming Circuit: Vacuum switching device with the specified protection and measurement arrangement
Outgoing Feeder: Vacuum switching device with the specified feeder protection and measurement arrangement
Transformer Feeder: Switching and protection arrangement for the transformer circuit
Bus Connection: Primary switching arrangement defined by the bus scheme
Metering Circuit: Measurement equipment required by the specified metering scheme
The XGN2-10 can be equipped with a vacuum contactor or vacuum circuit breaker according to the required switching duty.
The cubicle incorporates a five-prevention interlocking arrangement for controlled switching, isolation, earthing and access-related operations.
Project Configuration Requirements
The XGN2-10 configuration is determined from the project electrical schedule and circuit arrangement rather than the model number alone.
Electrical Data
- Rated current
- Short-circuit level
Project Data
- Number of cubicles
- Single-line diagram
Protection and Control Data
- Required protection functions
- Metering requirements
- Control requirements
- Status and alarm indication
Providing these inputs allows WWE to prepare the XGN2-10 configuration for quotation.
Engineering Drawing Confirmation
The XGN2-10 configuration is confirmed through project drawings before production release, giving the customer an opportunity to verify the proposed arrangement and external interfaces.
The drawing package may include:
General arrangement drawing - Cubicle dimensions, equipment layout and cable entry arrangement
Primary circuit diagram - Main circuit and switching connections
Secondary wiring diagram - Internal secondary connections
Terminal arrangement - External secondary connection points
Cable connection details - Interface with external cables
WWE reviews the required drawing scope with the customer before production. Any configuration changes identified during drawing confirmation are agreed before manufacturing.
Factory Inspection and Order Verification
Before shipment, the completed XGN2-10 cubicle is checked against the confirmed order configuration and the agreed inspection scope.
The inspection scope can cover:
Primary assembly: Verification of specified primary components and their installation positions
Secondary wiring: Check of wiring, terminal connections and component identification against the approved drawings
Mechanical operation: Verification of switching, isolating and earthing mechanisms
Interlocking: Functional check of the five-prevention interlocking sequence
Identification: Verification of nameplate data and major component identification against the confirmed configuration
Final assembly: Visual inspection of enclosure condition, internal assembly and connection points
WWE uses dedicated production and testing equipment for switchgear manufacturing, with more than 120 sets of production and testing equipment across its manufacturing facilities.
Where included in the agreed inspection scope, electrical test results and inspection records are retained as project documentation.

FAQ
Q: What is the MOQ for XGN2-10 medium voltage cubicles?
A: The MOQ is 1 cubicle, allowing buyers to place orders for individual replacement units, project extensions or small switchgear requirements without committing to a multi-cubicle order.
Q: What is the lead time for XGN2-10 medium voltage cubicles?
A: The standard production lead time is 30–45 days after order confirmation and receipt of the agreed advance payment. This period covers manufacturing and routine pre-shipment preparation; shipping time is not included.
Q: What payment terms are available for XGN2-10 orders?
A: The standard payment term is T/T, with 30% paid in advance and the remaining 70% settled before shipment. The payment schedule is stated in the commercial invoice or sales contract before production starts.
Q: How are XGN2-10 medium voltage cubicles packaged for export?
A: Export units are protected against handling and transportation damage and secured in export wooden cases. The packing arrangement is prepared for the dimensions, weight and shipping method of the ordered equipment.
Q: Can I arrange a third-party inspection before shipment?
A: Yes. A buyer-appointed inspection company can inspect the completed equipment before shipment. The inspection scope and inspection date should be agreed before the inspection is scheduled, and the third-party inspection cost is borne by the buyer.
Q: Are spare parts available for XGN2-10 medium voltage cubicles?
A: Yes. Spare parts can be ordered separately, including replacement components associated with the supplied cubicle. The required part number or component specification should be provided when requesting a spare-parts quotation.
Q: Does WWE provide English technical documentation for export orders?
A: Yes. English technical documentation is provided for export orders, allowing overseas buyers to use the supplied documents for project records, equipment identification and technical coordination.