Mv Switchgear Manufacturers is an indoor metal-clad withdrawable medium voltage switchgear assembly for three-phase AC power systems. It is used for medium voltage power distribution, feeder switching and circuit protection in substations and industrial electrical systems.

Technical Specifications
|
Parameter |
Specification |
|
Product Type |
Indoor metal-clad withdrawable MV switchgear |
|
Rated Voltage |
3.6 / 7.2 / 12 kV |
|
Rated Frequency |
50 Hz |
|
Rated Current |
630 / 1250 / 1600 / 2000 / 2500 / 3150 A |
|
Rated Short-Time Withstand Current |
16 / 20 / 25 / 31.5 / 40 kA, 4 s |
|
Rated Peak Withstand Current |
40 / 50 / 63 / 80 / 100 kA |
|
Rated Short-Circuit Breaking Current |
16 / 20 / 25 / 31.5 / 40 kA |
|
Power-Frequency Withstand Voltage |
24 / 32 / 42 kV |
|
Lightning Impulse Withstand Voltage |
40 / 60 / 75 kV |
|
Circuit Breaker |
Withdrawable vacuum circuit breaker |
|
Enclosure Protection |
IP4X with circuit breaker compartment door closed; IP2X with door open |
|
Installation |
Indoor |
|
Ambient Temperature |
-15°C to +40°C |
|
Relative Humidity |
≤95% daily average; ≤90% monthly average |
|
Installation Altitude |
≤1000 m |
|
Seismic Requirement |
≤8 magnitude |
Internal Construction
Circuit Breaker Compartment
Houses the withdrawable vacuum circuit breaker and its operating mechanism. The breaker is mounted on a movable handcart for movement between the defined operating and test positions.
Busbar Compartment
Contains the main busbar assembly used to connect the individual switchgear panels. The busbar rating is selected according to the required continuous current and short-circuit withstand level of the lineup.
Cable Compartment
Provides the connection space for medium voltage cables and associated primary components. The specified configuration accommodates up to nine single-core cables, subject to the cable size and termination arrangement.
Low-Voltage Compartment
Houses the secondary wiring and control equipment associated with protection, metering, indication and circuit breaker control.

Safety & Maintenance Features
Metal-Clad Compartmentalization
The metal-clad structure separates the main circuit and secondary equipment into defined compartments, providing controlled access during inspection and maintenance.
Withdrawable Breaker Maintenance
The withdrawable breaker arrangement allows the circuit breaker to be removed as a separate assembly for inspection or replacement without dismantling the complete switchgear panel.
Mechanical & Earthing Interlocks
The handcart and earthing mechanisms are mechanically coordinated to control breaker positions and the specified operating sequence, including service, test and earthing conditions.
Configuration Options
KYN28-12 panel configuration is determined by the feeder function, electrical ratings and protection scheme. The primary and secondary equipment are selected as a coordinated set rather than as independent components.
Feeder Function
- Ncoming feeder
- Outgoing feeder
- Transformer feeder
- Bus coupler
- Voltage transformer section
The feeder function determines the required primary circuit arrangement and associated protection functions.
Primary Circuit
- Vacuum circuit breaker
- Current transformer (CT)
- Voltage transformer (VT)
- Earthing switch
- Surge arrester
Breaker rating, CT/VT arrangement and cable termination are coordinated with the feeder electrical data.
Protection & Control
- Protection relay
- Metering equipment
- Indication devices
- Circuit breaker control components
The control arrangement is matched to the specified protection functions, measurement requirements and control voltage.
Configuration Review
The final panel arrangement is confirmed from the project single-line diagram, feeder schedule and technical specification before production.
Standards & Testing
Applicable Requirements
KYN28-12 is manufactured and tested according to the applicable medium voltage switchgear requirements and confirmed project specifications. The verification scope covers the enclosure, main circuit, insulation system, withdrawable mechanism, interlocking functions and secondary circuits.
Assembly Inspection
Each completed panel is inspected against the approved technical configuration to verify that the specified components, internal arrangement, wiring and nameplate data correspond with the approved documentation.
Mechanical Verification
The withdrawable breaker mechanism is operated through its defined positions to verify:
- Correct breaker insertion and withdrawal
- Service and test position indication
- Mechanical interlocking sequence
- Earthing mechanism operation
- Door and operating mechanism coordination
Electrical Verification
The main and secondary circuits are verified against the approved electrical configuration. Testing covers the specified insulation, control and protection circuits according to the applicable product requirements and project specification.
Where CTs, VTs, protection relays or other secondary components are specified, their installed configuration and wiring are checked against the approved technical documentation.
Final Inspection & Test Records
Before shipment, the completed panel is checked for component configuration, nameplate data, wiring, enclosure condition and mechanical operation.
Inspection and test records are prepared according to the confirmed product and project requirements, providing traceability between the completed panel, approved configuration and recorded inspection results.

Selection & Engineering Requirements
System Voltage: Confirm the system voltage and required switchgear rated voltage.
Fault Level: Confirm the prospective short-circuit current and required short-circuit withstand and breaking ratings.
Load Current: Confirm the continuous operating current for each incoming and outgoing circuit.
Cable Interface: Confirm cable size, quantity, termination arrangement and cable entry requirements.
Protection Scheme: Confirm the required protection functions and relay configuration.
CT / VT Data: Confirm CT and VT ratio, accuracy class and protection or metering requirements where applicable.
Environmental Conditions: Confirm ambient temperature, humidity, altitude and seismic requirements at the installation site.
FAQ
Q: Can KYN28-12 be used for retrofit or replacement projects?
A: KYN28-12 can be considered for retrofit or replacement projects when the existing system requirements and physical interface can be matched. Before replacement, the existing switchgear rated voltage, current, short-circuit level, cable arrangement, panel dimensions, busbar arrangement and protection scheme should be reviewed against the proposed configuration.
Q: What documents are normally required when evaluating a KYN28-12 supplier?
A: Typical evaluation documents include the product technical specification, general arrangement or dimensional drawings, component list, applicable test records, wiring information and commercial quotation. For project procurement, the required document set should also be checked against the customer's technical specification and approval procedure.
Q: What should be checked before approving a KYN28-12 technical offer?
A: The technical offer should be reviewed against the project specification and single-line diagram. Key points include the proposed electrical ratings, breaker configuration, feeder arrangement, major component selection, cable interface, protection and control requirements, environmental conditions and applicable technical requirements.
Q: What information should I include when requesting a KYN28-12 quotation?
A: A quotation request should include the system voltage, required rated current, short-circuit level, panel quantity, feeder functions and cable requirements. A single-line diagram, feeder schedule and project technical specification should also be provided when available so the proposed configuration can be reviewed accurately.
Q: What is the MOQ for KYN28-12 switchgear?
A: MOQ is confirmed according to the required panel quantity, configuration and project scope. Please provide the required panel quantity and technical specification for order confirmation.
Q: What is the lead time for KYN28-12 switchgear?
A: The stated lead time is 7–15 days for standard configurations. The confirmed schedule depends on panel quantity, component selection and the approved technical configuration.
Q: What payment methods are accepted for KYN28-12 switchgear orders?
A: We accept D/P, D/A, T/T and L/C. The applicable payment method and payment terms, including the stated 30% advance and 70% balance before shipment arrangement, are confirmed in the quotation and sales contract.