High Voltage Electrical Switchgear

High Voltage Electrical Switchgear

The KYN61-40.5 High Voltage Electrical Switchgear is a 40.5 kV indoor metal-clad withdrawable switchgear assembly for three-phase AC power receiving and distribution.
Send Inquiry
Description
Technical Parameters

The KYN61-40.5 High Voltage Electrical Switchgear is a 40.5 kV indoor metal-clad withdrawable switchgear assembly for three-phase AC power receiving and distribution.

 

QQ1762332701522

 

Technical Specifications

 

Parameter

Specification

Model

KYN61-40.5

Installation

Indoor

Product Type

Metal-clad withdrawable AC switchgear

Rated Voltage

40.5 kV

Rated Frequency

50 Hz

Rated Current

1250 / 1600 / 2000 / 2500 A

Rated Short-Circuit Breaking Current

20 / 25 / 31.5 kA

Rated Short-Time Withstand Current

20 / 25 / 31.5 kA, 4 s

Rated Peak Withstand Current

50 / 63 / 80 kA

Power-Frequency Withstand Voltage

95 kV / 1 min

Lightning Impulse Withstand Voltage

185 kV

Control Circuit Voltage

AC/DC 110 / 220 V

Enclosure Protection

IP3X

Circuit Breaker Compartment

IP2X with relevant door open

 

Four-Compartment Cabinet Architecture


The KYN61-40.5 uses metal partitions to separate the main functional areas of the cabinet, keeping the primary and secondary equipment arranged within dedicated compartments.


Relay & Instrument Compartment
The upper secondary compartment accommodates relay, control and instrument equipment required by the electrical scheme.


Circuit Breaker Compartment
The withdrawable circuit breaker handcart is installed in its dedicated compartment, with the associated primary connection arrangement located within the switching section.


Busbar Compartment
The main busbar system is housed in a separate compartment behind the metal partition.


Cable Compartment
The lower section provides the primary cable connection space and accommodates associated components including the current transformer and earthing switch.
The cabinet construction also incorporates an independent pressure-release channel. The internal arrangement includes the busbar bushing, contact box, cable connection, current transformer, earthing switch and pressure-release device.

 

Primary Equipment Arrangement


The KYN61-40.5 can be arranged with different handcart types according to the primary circuit requirements.


Circuit Breaker Handcart
The main withdrawable switching unit for circuit interruption and switching duties.


Isolation Handcart
Used where the approved primary scheme requires a withdrawable isolation arrangement.


Voltage Transformer Handcart
Used for withdrawable voltage transformer applications within the specified measurement or protection scheme.


Lightning Arrester Handcart
Used where lightning arrester equipment is included in the primary circuit.
The handcart frame is fabricated from steel plate through bending and welding.

 

4

 

Project Configuration Review


Primary circuit
The panel arrangement is established from the approved single-line diagram, including incoming, outgoing, transformer and bus-section circuits.


Primary equipment
The switching and measurement functions determine the required handcart and primary equipment arrangement.


Secondary system
Protection, measurement and control requirements determine the associated secondary equipment.


Compliance review
Electrical, environmental and project-specific requirements are checked before the final configuration is confirmed.

 

Typical Applications


Substation Incoming Circuits
Incoming panels form the receiving section of the lineup, connecting the upstream supply to the substation busbar.


Substation Feeder Circuits
Feeder panels distribute power from the busbar to downstream networks, transformers or connected loads.


Transformer Feeder Circuits
Transformer feeder panels provide the switching interface between the distribution lineup and connected power transformers.


Industrial Primary Distribution
In industrial substations, the lineup can combine incoming, feeder and transformer panels within the same indoor metal-clad arrangement.


Bus-Section and Bus-Coupling Circuits
A dedicated panel can separate or connect two bus sections when required by the approved distribution scheme.

 

Our Manufacturing


Manufacturing Scale
We operate manufacturing facilities covering more than 200,000 m² for electrical equipment production.


Production & Testing Resources
More than 120 production and testing equipment units are included across our manufacturing operation.


Switchgear Production
Our manufacturing scope includes high- and low-voltage switch equipment, covering the switchgear range that includes KYN61-40.5.


Annual Production
We produce more than 10,000 sets annually across high- and low-voltage switch equipment, motor starting equipment and reactive power compensation panels; this figure is not the output of KYN61-40.5 alone.


Product-Level Production
KYN61-40.5 production includes cabinet assembly, primary equipment integration and the installation of the specified secondary components within the defined cabinet structure.

 

Technical Information for RFQ


For quotation review, please provide the following documents where available:


Single-line diagram: Preferred for reviewing the required panel and lineup arrangement.


Project technical specification: Include project-specific electrical, environmental and compliance requirements.


Protection and control requirements: Provide the required protection, measurement and control scope.


CT/VT requirements: Include applicable ratios, classes and quantities where specified.


System requirements: Provide the applicable system voltage, current and short-circuit level.


If the complete project documentation is not yet available, the single-line diagram can be submitted first for an initial technical review.

 

FAQ

 

Q: What is the MOQ for KYN61-40.5 switchgear?

A: The MOQ is 1 complete switchgear panel. Multiple panels can be supplied as a complete switchgear lineup.

Q: What is the lead time for KYN61-40.5 switchgear?

A: The standard lead time is 30–60 days after drawing approval and order confirmation.

Q: What payment terms are available for KYN61-40.5 switchgear?

A: Standard payment terms are 30% T/T in advance and 70% before shipment. L/C at sight is also available for qualified orders.

Q: What warranty is provided for KYN61-40.5 switchgear?

A: The warranty period is 12 months from the shipment date, covering manufacturing defects under the agreed warranty terms.

Q: What technical documents are supplied with KYN61-40.5 switchgear?

A: The documentation package can include approved general arrangement drawings, electrical schematics, wiring diagrams, component lists, operation and maintenance documents, and factory test records.

Q: Is factory inspection available before shipment?

A: Pre-shipment inspection and factory acceptance testing can be arranged before shipment according to the approved technical specification and agreed inspection requirements.

Q: How is KYN61-40.5 switchgear packaged for international shipment?

A: The switchgear is packed in export-grade protective packaging and secured against movement and moisture during international transportation.

Q: What primary components are accommodated inside the KYN61-40.5 cabinet?

A: The cabinet construction includes the withdrawable handcart arrangement together with primary components such as the current transformer, earthing switch, busbar bushing and contact box. The actual component combination is established from the approved panel configuration.