Lv and Mv Switchgear

Lv and Mv Switchgear

LV and MV Switchgear covers coordinated low-voltage and medium-voltage switchgear assemblies used across transformer-fed power distribution systems for power receiving, distribution, switching, protection and control.
Send Inquiry
Description
Technical Parameters

LV and MV Switchgear covers coordinated low-voltage and medium-voltage switchgear assemblies used across transformer-fed power distribution systems for power receiving, distribution, switching, protection and control.

 

product-474-277

 

Technical Specifications

 

Parameter

Specification

Product type

Indoor metal-clad withdrawable MV switchgear

Model

KYN28-12

Rated voltage

3.6 / 7.2 / 12 kV

Rated frequency

50 Hz

Rated current

630 / 1250 / 1600 / 2000 / 2500 / 3150 A

Short-time withstand current

16 / 20 / 25 / 31.5 / 40 kA

Peak withstand current

40 / 50 / 63 / 80 / 100 kA

Rated short-circuit breaking current

16 / 20 / 25 / 31.5 / 40 kA

Power-frequency withstand voltage

24 / 32 / 42 kV

Lightning impulse withstand voltage

40 / 60 / 75 kV

Protection degree

IP4X with door closed; IP2X with door open

Installation

Indoor

Ambient temperature

-15°C to +40°C

Relative humidity

≤95% daily average; ≤90% monthly average

Maximum altitude

≤1000 m

Seismic requirement

Up to magnitude 8

Circuit breaker

Withdrawable vacuum circuit breaker handcart

Circuit breaker positions

Service, test and disconnected positions

 

The specifications below define the KYN28-12 MV switchgear section presented on this page. LV equipment is coordinated according to the project distribution requirements.

 

Switchgear Construction


LV and MV switchgear use functional sections for power connection, distribution, switching, protection and control, with the internal layout determined by the circuit function and selected equipment.


Incoming and Busbar Section
The incoming section connects the supply to the main busbar, which distributes power to downstream circuits. Switching, protection and metering equipment is arranged according to the feeder requirements.


Outgoing Feeder Section
Outgoing feeder sections connect the switchgear to transformers, motors and other downstream loads. The feeder arrangement is determined by load current, circuit function and protection requirements.


Cable Connection Section
The cable section provides termination space for incoming and outgoing cables and associated primary components. The KYN28-12 cable compartment can accommodate up to nine single-core cables where applicable.


Control and Protection Section
The control section houses protection, metering, indication and control components required for the selected circuit and operating scheme.


Withdrawable Circuit Breaker Compartment
The KYN28-12 uses a withdrawable vacuum circuit breaker handcart with service, test and disconnected positions for operation, testing and maintenance.

 

IMG2155

 

LV & MV Switchgear System Configuration


MV Incoming and Distribution
The MV section handles incoming, outgoing, transformer feeder and bus coupler circuits within the medium-voltage distribution system.


Transformer Interface
The transformer connects the MV distribution section with the LV main switchgear, transferring power from the MV primary side to the LV distribution side.


LV Main and Feeder Distribution
The LV section receives the transformer secondary supply and distributes power through main incoming and outgoing feeder circuits to downstream loads.


Distribution Flow
The overall arrangement follows the project electrical architecture:
MV Incoming → MV Switchgear → Transformer → LV Switchgear → Downstream Loads

 

IMG2158

 

Configuration Options


MV Configuration
KYN28-12 can be configured for incoming, outgoing, transformer feeder, bus coupler, VT and metering circuits, with compatible vacuum circuit breakers, CTs, VTs, earthing switches, surge arresters and protection equipment. VS1 and VD4 vacuum circuit breaker arrangements are available where compatible with the selected configuration.


LV Configuration
LV switchgear can be configured for main incoming, bus coupler, outgoing feeder, motor control and metering circuits according to the required load and protection scheme.

 

LV & MV Engineering Coordination


Voltage and Transformer Rating
The MV system voltage, transformer secondary voltage and transformer rating must match the specified LV switchgear voltage and current requirements.


Short-Circuit Rating
The upstream fault level and transformer impedance determine the prospective short-circuit current used to specify the withstand and breaking ratings of the LV and MV switchgear.


Protection Coordination
MV feeder, transformer and LV feeder protection must be coordinated according to the approved protection scheme, including the required protection devices and relay settings.


Metering and Control
MV and LV metering and control interfaces are defined according to the required measurement points and approved electrical control scheme.

 

Safety & Protection


Five-Prevention Interlocking
The KYN28-12 incorporates five-prevention mechanical interlocking to control defined operating sequences involving the circuit breaker, earthing switch and cabinet access.


Earthing
The KYN28-12 grounding system provides the required connection between the metal enclosure and the switchgear earthing circuit.


Pressure Relief
The relevant MV compartments incorporate pressure-relief provisions to provide a designated discharge path in the event of an internal fault causing rapid pressure rise.

 

Applications


Transformer-Fed Distribution
LV and MV switchgear can be applied where medium-voltage incoming power is stepped down through a transformer and distributed through LV main and feeder sections.


Industrial LV/MV Distribution
LV and MV switchgear can be coordinated where medium-voltage receiving and transformer protection are followed by low-voltage distribution to motors, production equipment and auxiliary loads.


Substation Distribution
Substation arrangements can combine MV incoming, outgoing and transformer circuits with LV main distribution for downstream power supply.

 

Factory Testing & Inspection


Factory inspection verifies the completed switchgear against the approved configuration, drawings and applicable technical requirements.


Assembly Inspection
The completed lineup is checked for cabinet assembly, component installation, wiring, labeling and physical condition.


Mechanical Inspection
Mechanical checks cover relevant operating mechanisms, breaker movement, handcart positioning, door operation, earthing switch operation and interlocking functions.


Electrical Inspection
Electrical inspection covers relevant wiring, continuity, insulation and applicable routine test requirements defined by the product specification and project requirements.


Protection and Control Verification
Protection, metering, indication and control circuits are checked against the approved circuit diagrams and equipment configuration.


Factory Acceptance Testing
FAT can be arranged when required by the project inspection plan.


The final inspection scope is confirmed against the actual equipment configuration so that the inspection covers the supplied LV or MV equipment rather than applying an identical test package to every project.

 

FAQ

 

Q: What information is required to request an LV and MV switchgear quotation?

A: Please provide the single-line diagram, system voltage, rated current, short-circuit level, feeder schedule, transformer data, protection requirements and applicable project specifications. These documents are used to prepare the switchgear configuration and quotation.

Q: Can you manufacture LV and MV switchgear according to project drawings?

A: Yes. Switchgear can be configured according to approved single-line diagrams, technical specifications, feeder schedules and project drawings. The final configuration is confirmed during technical review before production.

Q: Can I request technical drawings before placing an order?

A: Yes. Technical drawings can be provided for project review after the required equipment configuration and technical parameters have been confirmed.

Q: What is the MOQ for LV and MV switchgear?

A: The MOQ is 1 set for project orders. The required quantity can include individual switchgear panels or a complete LV/MV lineup according to the project scope.

Q: What is the typical lead time for LV and MV switchgear?

A: The typical production lead time is 30 days after technical requirements and drawings are confirmed. Projects requiring special components, additional testing or customized configurations may require a longer production schedule.

Q: What payment terms are available for LV and MV switchgear?

A: Standard payment terms are 30% T/T in advance and 70% balance before shipment. L/C can be considered for qualifying project orders.

Q: Can the buyer arrange a factory inspection before shipment?

A: Yes. Customer or third-party factory inspection can be arranged before shipment according to the agreed inspection scope and schedule.

Q: What technical documents are supplied with the switchgear?

A: The documentation package can include approved technical drawings, wiring diagrams, equipment documentation and applicable factory inspection records. The required document list is confirmed during the technical review.